Guided wave radar level transmitter
 
◆ Model:RF2000D
◆ Parameters:RF2000D、、、、

View product specs

Product Overview

RF series guided wave radar level transmitter has all-round quality assurance which is approved by experienced experts in the field of radar level gauge. RF series has several models and installation modes and is applicable for nearly all the liquid measurement as well as level measurement like dust, flour, sand and similar granular substance. It is substitution of displacer level transmitters or magnetic liquid indicator. It has lots of advantages, for instance, measuring precision unaffected by the medium density, temperature or pressure etc; easy to install and debug; operation only by inputting data configuration. It is an advanced level gauge, which is widely applied in the petroleum, chemical, electricity, metallurgy, pharmacy, foodstuff and grain storage industry.



Structure Principle

RF2000 Guided wave radar level Transmitter
  A Side mounted-single probe-external caged displacer
Recommend Use water solution, crude oil, hydrocarbon fluids,hydrocarbon polymer
Not recommended liquid sulfur,solid medium, high viscosity medium
Min. dielectric constant and Max. measure height:1.46m2.09m4.06m
Dielectric constant range1.4100 Medium viscosity:≤1000cp
B Top mounted coaxial probe
Recommend Use clean low viscosity hydrocarbon polymer&hydrocarbon fluids 
Not recommended heavy attachment,high viscosity or scaling applications 
Min. dielectric constant and Max. measure height:1.46m2.09m4.06m
dielectric constant range1.4100 medium viscosity:≤500cp
C Top mounted single probe (cable)
Recommend Use water solution, crude oil,hydrocarbon fluids,high viscosity and foaming medium
Not recommended hydrocarbon polymer, liquid sulfur,low dielectric constant medium(eg.plastic powder)
Min. dielectric constant and Max. measure height:1012m3520m
dielectric constant range10100 medium viscosity:≤1500cp
D Top mounted dual probe (cable)
Recommend Use crude oil,hydrocarbon,hydrocarbon polymer,liquid sulfur,light attachment 
Not recommended fixed material level, easy scaling and polymerization applications
Min. dielectric constant and Max. measure height1.96m1030m
dielectric constant range1.9100 medium viscosity:≤1000cp
  L 316Lstd
M Monel alloy 
H Hastelloy C-276
F  PTFE lined  (for A and D only)
G Zirconium(Zr)
T Titanium (Ti)
  1 1.5''NPT
2 2''NPT
3 1.5'' sanitary trefoil clamp 
4 DN401.5''
5 DN502.5''
6 DN803''
7 DN1004''
8 DN20 (for  probe type A only)
9 DN25 (for  probe type A only)
  0 PN 2.5Mpa
1 PN 5.0Mpa
2 PN 6.4Mpa
3 PN 10Mpa
4 PN 16Mpa
5 Class 150LB ANSI
6 Class 300LB ANSI
7 Class 400LB ANSI
8 Class 600LB ANSI
9 Class 900LB ANSI
  D  -50204
E sanitary std tpe: -40℃~204
H  -50℃~427
  D Explosion-proof: ExdIICT4T6
E Intrinsic safe: ExiaIICT4T6
  L liquid level 
A interface 
F material levelpowderymeasure
P material level (Tablet/particle) measure
  mm
           mm